My WS boot disk has failed so when i want to boot system (by OK boot -s or Ok boot disk0 ) i get these mesgs:
disk read error
boot :can not find misc/sparc9v/krtld
boot:error loading interperetor (misc/sparc9v/krtld)
Elf64 read error.
boot failed.
although it's probed ,finally i try... (1 Reply)
Hi All,
Seems to be one of the disk has failed on my Solaris server.
How do i confirm that disk has really failed or not?
Here are alert details.
-------
iostat -En out/put
c1t3d0 Soft Errors: 1884 Hard Errors: 153 Transport Errors: 54
Vendor: FUJITSU Product:... (3 Replies)
i'm writing some code to simulate the boot progress after power on
but when i try to read the 2nd sector from a floppy disk, this operation always fail with ah=0x80h which means timeout, how can i get over this problem?
my code would be like this:
$ cat boot.S
.code16
#define SETUPLEN 4... (0 Replies)
i'm writing some code to simulate the boot progress after power on
but when i try to read the 2nd sector from a floppy disk, this operation always fail with ah=0x80h which means timeout, how can i get over this problem?
my code would be like this:
$ cat boot.S
.code16
#define SETUPLEN 4... (0 Replies)
i'm writing some code to simulate the boot progress after power on
but when i try to read the 2nd sector from a floppy disk, this operation always fail with ah=0x80h which means timeout, how can i get over this problem?
my code would be like this:
$ cat boot.S
.code16
#define SETUPLEN 4... (0 Replies)
I have an oldish Solaris 10 system (SunFire x4240), which due to a recent heating event in the server room, lost it's system disk.
I have rsync backups of all the other (data) disks, but apparently I do not have a backup of /. :-( I can start the machine up in failsafe mode, but running fsck on... (4 Replies)
Iam new to AIX
I am unable varyonvg on the vios,some of the disk are reported as harware failure.
I am going to replace the disk,Please tell me how to remove the disk without any corruption in the VG
lspv -l hdiskx also didn't work (0 Replies)
Hi
Please can you help me on replacing or removing a faulty disk drive on a SUN NETRA X4250server with 4 internal drives only.
the format comand show me the following:
format
Searching for disks...done
AVAILABLE DISK SELECTIONS:
0. c0t0d0 <drive type unknown>
... (9 Replies)
Discussion started by: fretagi
9 Replies
LEARN ABOUT NETBSD
arcmsr
ARCMSR(4) BSD Kernel Interfaces Manual ARCMSR(4)NAME
arcmsr -- Areca Technology Corporation SATA/SAS RAID controller
SYNOPSIS
arcmsr* at pci? dev ? function ?
DESCRIPTION
The arcmsr driver provides support for the PCI-X and PCI Express RAID controllers from Areca Technology Corporation:
- ARC-1110 PCI-X 4 Port SATA RAID Controller
- ARC-1110ML PCI-X 4 Port SATA RAID Controller
- ARC-1120 PCI-X 8 Port SATA RAID Controller
- ARC-1120ML PCI-X 8 Port SATA RAID Controller
- ARC-1130 PCI-X 12 Port SATA RAID Controller
- ARC-1130ML PCI-X 12 Port SATA RAID Controller
- ARC-1160 PCI-X 16 Port SATA RAID Controller
- ARC-1160ML PCI-X 16 Port SATA RAID Controller
- ARC-1170 PCI-X 24 Port SATA RAID Controller
- ARC-1200 Rev A PCI Express 2 Port SATA RAID Controller
- ARC-1202 PCI Express 2 Port SATA RAID Controller
- ARC-1210 PCI Express 4 Port SATA RAID Controller
- ARC-1220 PCI Express 8 Port SATA RAID Controller
- ARC-1230 PCI Express 12 Port SATA RAID Controller
- ARC-1230ML PCI Express 12 Port SATA RAID Controller
- ARC-1231ML PCI Express 12 Port SATA RAID Controller
- ARC-1260 PCI Express 16 Port SATA RAID Controller
- ARC-1260ML PCI Express 16 Port SATA RAID Controller
- ARC-1261ML PCI Express 16 Port SATA RAID Controller
- ARC-1280 PCI Express 24 Port SATA RAID Controller
- ARC-1280ML PCI Express 24 Port SATA RAID Controller
- ARC-1680 PCI Express 8 Port SAS RAID Controller
- ARC-1680LP PCI Express 8 Port SAS RAID Controller
- ARC-1680i PCI Express 8 Port SAS RAID Controller
- ARC-1680x PCI Express 8 Port SAS RAID Controller
- ARC-1681 PCI-X 8 Port SAS RAID Controller
These controllers support RAID levels 0, 1, 1E, 3, 5, 6, and JBOD using either SAS or SATA II drives.
arcmsr supports management and monitoring of the controller through the bioctl(8) and envstat(8) commands.
Please note, however, that to use some features that require special privileges, such as creating/removing hot-spares, pass-through disks or
RAID volumes will require to have the password disabled in the firmware; otherwise a Permission denied error will be reported by bioctl(8).
When a RAID 1 or 1+0 volume is created, either through the bioctl(8) command or controller's firmware, the volume won't be accessible until
the initialization is done. A way to get access to the sd(4) device that corresponds to that volume without rebooting, is to issue the fol-
lowing command (once the initialization is finished):
$ scsictl scsibus0 scan any any
The arcmsr driver will also report to the kernel log buffer any error that might appear when handling firmware commands, such as used by the
bioctl(8) command.
EVENTS
The arcmsr driver is able to send events to powerd(8) if a volume or any drive connected to the volume is not online. The state-changed
event will be sent to the /etc/powerd/scripts/sensor_drive script when such condition happens.
SEE ALSO intro(4), pci(4), scsi(4), sd(4), bioctl(8), envstat(8), powerd(8), scsictl(8)HISTORY
The arcmsr driver first appeared in NetBSD 5.0.
AUTHORS
The arcmsr driver was originally written for OpenBSD by David Gwynne. It was ported to NetBSD and extended by Juan Romero Pardines.
BSD March 3, 2008 BSD