Linux and UNIX Man Pages

Linux & Unix Commands - Search Man Pages

mpt-status(8) [suse man page]

MPT-STATUS(8)						      System Manager's Manual						     MPT-STATUS(8)

NAME
mpt-status - retrieve configuration and health status from LSI hardware RAID controllers SYNOPSIS
mpt-status [ options ] DESCRIPTION
The mpt-status software is a query tool to access the running configuration and status of LSI SCSI HBAs. mpt-status allows you to monitor the health and status of your RAID setup. OPTIONS
--autoload This will try to automatically load the mptctl kernel module. -u --controller <int> Set the IOC unit (controller). -h --help Print some help information. -n --newstyle Use the new style output. This parameter was introduced to retain backwards compatibility. If not set, you get the old style output. It is very likely that the output of the newstyle format will change heavily in the future, so do not rely on it when writing plug- ins for monitoring software, for example. -i --set_id <int> Set id of primary device (check README). -p --probe_id Use this to probe SCSI id's when not on id 0. -q --quiet Do not display any warnings. -s --status_only Only print the status information. This can be used for easy scripting -v --verbose Print verbose information, such as warnings -V --version Print version information -d --debug [<int>] Enable debugging and set level optionally. NOTE: This is not fully implemented yet. DIAGNOSTICS
The program's exit(2) status is meant to be interpreted as a bit mask. If everything went well, zero is returned. If not (i.e. if for exam- ple an error or unknown condition is detected), the bits of the return value shall be interpreted as: Bit Value Meaning ----------------------------------------------------------------- 0 1 Abnormal condition / unknown error 1 2 A logical volume has failed 2 4 A logical volume is degraded 3 8 A logical volume is resyncing 4 16 At least one physical disk failed 5 32 At least one physical disk is in warning condition REPORTING BUGS
Report bugs to your linux distribution or software vendor, if mpt-status was bundled on your installation. If you have been compiling mpt- status from the vanilla sources and experience problems, redirect them to preferably <ratz@drugphish.ch> or <rnibali@pyx.ch>. BUGS
Besides design bugs, gross software engineering and missing features, this software is considered pretty stable and can be used in produc- tion environments. FILES
/dev/mptctl SEE ALSO
LSI Logic provides CLI tools for megaraid controllers which you can find on their webpage, following http://www.lsil.com/cm/Download- Search.do AUTHOR
mpt-status was written by Roberto Nibali <ratz@drugphish.ch>. This manual page was written by Steffen Joeris <steffen.joeris@skolelinux.de>, for the Debian project (but may be used by others). November 2006 MPT-STATUS(8)

Check Out this Related Man Page

MPTUTIL(8)						    BSD System Manager's Manual 						MPTUTIL(8)

NAME
mptutil -- Utility for managing LSI Fusion-MPT controllers SYNOPSIS
mptutil version mptutil [-u unit] show adapter mptutil [-u unit] show config mptutil [-u unit] show drives mptutil [-u unit] show events mptutil [-u unit] show volumes mptutil [-u unit] fail drive mptutil [-u unit] online drive mptutil [-u unit] offline drive mptutil [-u unit] name volume name mptutil [-u unit] volume status volume mptutil [-u unit] volume cache volume enable|disable mptutil [-u unit] clear mptutil [-u unit] create type [-q] [-v] [-s stripe_size] drive[,drive[,...]] mptutil [-u unit] delete volume mptutil [-u unit] add drive [volume] mptutil [-u unit] remove drive DESCRIPTION
The mptutil utility can be used to display or modify various parameters on LSI Fusion-MPT controllers. Each invocation of mptutil consists of zero or more global options followed by a command. Commands may support additional optional or required arguments after the command. Currently one global option is supported: -u unit unit specifies the unit of the controller to work with. If no unit is specified, then unit 0 is used. Volumes may be specified in two forms. First, a volume may be identified by its location as [xx:]yy where xx is the bus ID and yy is the target ID. If the bus ID is omitted, the volume is assumed to be on bus 0. Second, on the volume may be specified by the corresponding daX device, such as da0. The mpt(4) controller divides drives up into two categories. Configured drives belong to a RAID volume either as a member drive or as a hot spare. Each configured drive is assigned a unique device ID such as 0 or 1 that is show in show config, and in the first column of show drives. Any drive not associated with a RAID volume as either a member or a hot spare is a standalone drive. Standalone drives are visible to the operating system as SCSI disk devices. As a result, drives may be specified in three forms. First, a configured drive may be identi- fied by its device ID. Second, any drive may be identified by its location as xx:yy where xx is the bus ID and yy is the target ID for each drive as displayed in show drives. Note that unlike volumes, a drive location always requires the bus ID to avoid confusion with device IDs. Third, a standalone drive that is not part of a volume may be identified by its corresponding daX device as displayed in show drives. The mptutil utility supports several different groups of commands. The first group of commands provide information about the controller, the volumes it manages, and the drives it controls. The second group of commands are used to manage the physical drives attached to the con- troller. The third group of commands are used to manage the logical volumes managed by the controller. The fourth group of commands are used to manage the drive configuration for the controller. The informational commands include: version Displays the version of mptutil. show adapter Displays information about the RAID controller such as the model number. show config Displays the volume and drive configuration for the controller. Each volume is listed along with the physical drives that the volume spans. If any hot spare drives are configured, then they are listed as well. show drives Lists all of the physical drives attached to the controller. show events Display all the entries from the controller's event log. Due to lack of documentation this command is not very useful currently and just dumps each log entry in hex. show volumes Lists all of the logical volumes managed by the controller. The physical drive management commands include: fail drive Mark drive as ``failed requested''. Note that this state is different from the ``failed'' state that is used when the firmware fails a drive. Drive must be a configured drive. online drive Mark drive as an online drive. Drive must be part a configured drive in either the ``offline'' or ``failed requested'' states. offline drive Mark drive as offline. Drive must be a configured, online drive. The logical volume management commands include: name volume name Sets the name of volume to name. volume cache volume enable|disable Enables or disables the drive write cache for the member drives of volume. volume status volume Display more detailed status about a single volume including the current progress of a rebuild operation if one is being performed. The configuration commands include: clear Delete the entire configuration including all volumes and spares. All drives will become standalone drives. create type [-q] [-v] [-s stripe_size] drive[,drive[,...]] Create a new volume. The type specifies the type of volume to create. Currently supported types include: raid0 Creates one RAID0 volume spanning the drives listed in the single drive list. raid1 Creates one RAID1 volume spanning the drives listed in the single drive list. raid1e Creates one RAID1E volume spanning the drives listed in the single drive list. Note: Not all volume types are supported by all controllers. If the -q flag is specified after type, then a ``quick'' initialization of the volume will be done. This is useful when the drives do not contain any existing data that need to be preserved. If the -v flag is specified after type, then more verbose output will be enabled. Currently this just provides notification as drives are added to volumes when building the configuration. The -s stripe_size parameter allows the stripe size of the array to be set. By default a stripe size of 64K is used. The list of valid values for a given type are listed in the output of show adapter. delete volume Delete the volume volume. Member drives will become standalone drives. add drive [volume] Mark drive as a hot spare. Drive must not be a member of a volume. If volume is specified, then the hot spare will be dedicated to that volume. Otherwise, drive will be used as a global hot spare backing all volumes for this controller. Note that drive must be as large as the smallest drive in all of the volumes it is going to back. remove drive Remove the hot spare drive from service. It will become a standalone drive. EXAMPLES
Mark the drive at bus 0 target 4 as offline: mptutil offline 0:4 Create a RAID1 array from the two standalone drives da1 and da2: mptutil create raid1 da1,da2 Mark standalone drive da3 as a global hot spare: mptutil add da3 SEE ALSO
mpt(4) HISTORY
The mptutil utility first appeared in FreeBSD 8.0. BUGS
The handling of spare drives appears to be unreliable. The mpt(4) firmware manages spares via spare drive ``pools''. There are eight pools numbered 0 through 7. Each spare drive can only be assigned to a single pool. Each volume can be backed by any combination of zero or more spare pools. The mptutil utility attempts to use the following algorithm for managing spares. Global spares are always assigned to pool 0, and all volumes are always backed by pool 0. For dedicated spares, mptutil assigns one of the remaining 7 pools to each volume and assigns dedicated drives to that pool. In practice however, it seems that assigning a drive as a spare does not take effect until the box has been rebooted. Also, the firmware renumbers the spare pool assignments after a reboot which undoes the effects of the algorithm above. Simple cases such as assigning global spares seem to work ok (albeit requiring a reboot to take effect) but more ``exotic'' configurations may not work reliably. Drive configuration commands result in an excessive flood of messages on the console. The mpt version 1 API that is used by mptutil and mpt(4) does not support volumes above two terabytes. This is a limitation of the API. If you are using this adapter with volumes larger than two terabytes, use the adapter in JBOD mode. Utilize geom(8), zfs(8), or another soft- ware volume manager to work around this limitation. BSD
August 16, 2009 BSD
Man Page